久草精品视频在线播放,中文人妻AV久久人妻水密桃,av免费观看精品,亚洲五月激情综合图片区 日本成熟少妇A∨网站,久久看亚洲欧美,久久久久久人妻精品一区,久久亚洲Aⅴ无码影院

產(chǎn)品中心

小鼠基質(zhì)金屬蛋白酶原-9(Pro-MMP-9)微量上樣酶聯(lián)免疫吸附檢測試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK8500MS
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00
96T*5 ¥13600.00

Overview

Product name: Mouse Pro-MMP-9(Pro-Matrix Metalloproteinase 9) Microsample ELISA Kit
Reactivity: Mouse
Alternative Names: Pro-MMP-9
Assay Type: Sandwich
Sensitivity: 0.478 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;Cardiovascular biology;Hepatology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse Pro-MMP-9. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse Pro-MMP-9. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse Pro-MMP-9, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse Pro-MMP-9 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.225 2.143
25.00 1.590 1.508
12.50 1.029 0.947
6.25 0.850 0.768
3.13 0.486 0.404
1.56 0.363 0.281
0.78 0.173 0.091
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant Pro-MMP-9 and the recovery rates were calculated by comparing the measured value to the expected amount of Pro-MMP-9 in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 98%
EDTA plasma(n=5) 91-112% 102%
Heparin plasma(n=5) 93-118% 106%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Pro-MMP-9 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-108% 84-113% 83-99% 90-102%
EDTA plasma(n=5) 90-104% 94-118% 90-115% 91-96%
Heparin plasma(n=5) 87-102% 91-118% 87-109% 91-111%

產(chǎn)品成分表