久草精品视频在线播放,中文人妻AV久久人妻水密桃,av免费观看精品,亚洲五月激情综合图片区 日本成熟少妇A∨网站,久久看亚洲欧美,久久久久久人妻精品一区,久久亚洲Aⅴ无码影院

產(chǎn)品中心

小鼠血小板衍生生長因子A(PDGFA)酶聯(lián)免疫吸附檢測試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK4822
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)(2)

Product name: Mouse PDGFA(Platelet Derived Growth Factor Subunit A) ELISA Kit
Reactivity: Mouse
Alternative Names: PDGF-A; PDGF1; Platelet Derived Growth Factor Alpha Polypeptide
Assay Type: Sandwich
Sensitivity: 31 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample type: Serum, plasma and other biological fluids.
Assay length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;Bone metabolism;
Uniprot ID: P20033
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse PDGFA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse PDGFA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse PDGFA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse PDGFA in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.172 2.077
2500.00 1.602 1.507
1250.00 1.113 1.018
625.00 0.863 0.768
312.50 0.529 0.434
156.25 0.336 0.241
78.13 0.228 0.133
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PDGFA and the recovery rates were calculated by comparing the measured value to the expected amount of PDGFA in samples.
Matrix Recovery range Average
serum(n=5) 88-99% 93%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PDGFA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 93-105% 82-101% 91-103%
EDTA plasma(n=5) 83-95% 88-102% 85-97% 80-92%
Heparin plasma(n=5) 83-97% 81-103% 89-101% 81-98%
關(guān)閉